Mechy Try it free

Learn

Does Heating Oil Freeze?

In short

Not the way water does. Heating oil turns to wax as it cools. No. 2 heating oil is close to No. 2 diesel, which typically starts to cloud with wax at about 14°F (-10°C) and stops pouring roughly 6 to 20°F below that. The wax plugs the filter or a thin outdoor line first, so the burner can quit long before the tank turns thick. Kerosene (No. 1) holds out to about -40°F. Water in the tank is the other cold problem, and that does freeze, at 32°F.

Stuck on this? Snap a photo and ask Mechy. It makes the steps for what you have, with tools, parts and a moving drawing for each. First guide free. No sign-up, no card.

Snap a photo, ask Mechy

Heating oil gel temperature chart

In the US, heating oil means No. 2 fuel oil, per the EIA. These are the numbers the sources give. Your oil company can tell you the cloud point of what they actually deliver.

FuelStarts to cloud (cloud point)Stops pouring (pour point)Source
No. 2 oil, typicalAbout 14°F (-10°C). Commonly -18°F to +20°F, sometimes up to +40°F6 to 10°F below the cloud point (Chevron), 10 to 20°F below (Filter Manufacturers Council)Cenex, Filter Manufacturers Council, Chevron (all for No. 2 diesel)
No. 2 fuel oil, the standard's limitNot in the table21°F (-6°C) at mostASTM D396, as printed in Chevron's review
No. 1 fuel oil, the standard's limitNot in the table0°F (-18°C) at mostASTM D396, as printed in Chevron's review
Kerosene or No. 1 dieselNear -40°F (-40°C)Near -40°F (-40°C)Filter Manufacturers Council
Bioheat B20About 2 to 7°F higher than straight No. 2Not givenClean Fuels Alliance America
Water in the tank or lineFreezes at 32°F (0°C)Ice can block the lineNova Scotia tank guide

The ASTM limits are ceilings, not what most oil does. Still, oil that meets the standard can stop pouring at 21°F. If your tank is outside, tell your oil company and ask what they deliver for it.

Is heating oil the same as diesel?

Close. The EIA says the same No. 2 distillate can be used as either diesel fuel or fuel oil. Chevron calls No. 2 fuel oil similar, but not identical, to No. 2-D diesel, and kerosene similar to No. 1-D. Heating oil is made to the fuel oil standard, ASTM D396, and diesel to ASTM D975. How the two diesel grades compare is on our page about No. 1 vs No. 2 diesel.

So the diesel numbers are a fair guide, and the same paraffin wax is behind both problems. For diesel in a tractor or a machine, see at what temperature diesel gels.

Why the burner quits before the tank gels

  • The filter goes first. Wax crystals coat the filter element and cut the flow, per the Filter Manufacturers Council. Chevron says some fuel systems plug right at the cloud point and many run several degrees below it.
  • Cold oil burns badly even before it waxes. Beckett says No. 2 fuel oil thickens from 35 SSU at 100°F to 52 SSU at 30°F (SSU is a measure of viscosity). That raises the nozzle's flow by about 10% and makes bigger droplets. The result can be delayed ignition, a poorly shaped flame, smoke, or no ignition at all.
  • Water freezes in low spots. The Nova Scotia tank guide says to run an outdoor supply line on a downward slope from the tank to the building, so water can't collect in it and freeze.

Outdoor tanks are the ones at risk

An outdoor tank and its line sit in the weather. Nova Scotia's guide says to put the tank indoors whenever you can: outdoors, the weather causes corrosion and condensation inside the tank. For a tank that stays outside, the guide and Beckett say:

PartWhat the sources say
TankMove an above-ground tank inside, or bury it below the frost line (Beckett)
Supply lineInsulate it (Beckett). Copper at least 3/8 in OD, and 1/2 in OD outside the house to reduce freezing. Slope it down to the building, give it at least one horizontal loop for frost heave, and protect it from the weight of snow and ice (Nova Scotia)
Heat tapeOnly if it suits the job and your local building and electrical codes allow it (Beckett)
FilterInside the building, near the burner, 50 microns or finer (Beckett NX manual). Serviced at least once a year (Nova Scotia)

What to do if your heating oil has gelled

  1. Don't keep pressing the reset button. Beckett's NX burner manual says the appliance has to be free of oil and oil vapor before you start or reset the burner. Starting it with oil pooled in the chamber, the chamber full of vapor or very hot can cause a puff-back or a fire, the manual warns. After three lockouts in a row, that control locks out until a qualified service technician resets it. Other burners differ, so read yours.
  2. Check the tank gauge. An empty tank stops the burner too.
  3. Call your oil company or heating service. Tell them the tank is outside and the oil may have gelled.
  4. Warm the oil above its cloud point. The crystals don't go away on their own while it's cold, and Cenex says blending afterwards doesn't remove the ones already formed. Keep open flame away from the tank, the line and the filter.
  5. Replace the plugged filter. The wax is in it. The pump may then need bleeding: the burner manual covers it, or leave it to the service tech.
  6. Fix the oil before the next cold night. Blend it or treat it while it's warm, or it can gel again.

If the house will sit empty in a cold snap, Beckett's NX manual warns that a burner lockout or a power cut can freeze the plumbing within hours. The protection it suggests is an alarm that senses low temperature and keeps working in a power cut.

How to keep heating oil from gelling

  • Ask for a winter blend. Kerosene lowers the cloud point. Chevron and Cenex say each 10% of No. 1 lowers the cloud point of No. 2 by about 3°F, so dropping it 10°F takes more than 30%. Cenex's rule for diesel is to switch about 15°F above the cloud point, or once nights get near 30°F. Check your burner's manual or ask your service company before you change fuel.
  • Treat early, not late. Beckett suggests fuel oil treatments that lower the cloud and pour points, and says to ask your oil distributor what works locally. Chevron says these additives have to go in while the oil is above its cloud point.
  • Know what additives can't do. Sources differ here. The Filter Manufacturers Council says cold-flow improvers lower the pour point but not the cloud point, and only diluting with No. 1 or kerosene lowers the cloud point. Chevron lists some additives that lower the cloud point a few degrees.
  • Keep water out. Beckett's NX manual says to keep the tank full, especially in summer, so moisture doesn't condense inside it. Nova Scotia's guide says to have sludge and water removed from the tank every year.
  • Know your blend. Higher Bioheat blends cloud a few degrees warmer, so expect B20 to cloud a little sooner than straight No. 2.

The same cold that gels oil freezes other fluids at their own points: DEF freezes near 12°F. More on how machines work is in Learn.

No heat and not sure it's the oil? Snap the burner, the filter and the tank gauge, and ask Mechy what to check first.

Questions

At what temperature does heating oil gel?

It depends on the oil. No. 2 heating oil is close to No. 2 diesel, which typically starts to form wax at about 14°F (-10°C) and stops pouring roughly 6 to 20°F below that. The filter and a thin outdoor line can plug before the tank turns thick. Ask your oil company for the cloud point of what they deliver.

What temperature does heating oil freeze at?

It doesn't freeze solid at 32°F the way water does. It turns cloudy with wax at its cloud point and gels lower down. Water in the tank or line is different: it freezes at 32°F (0°C) and can block the line.

Is No. 2 fuel oil the same as diesel?

Close, but not the same. The EIA says the same No. 2 distillate can be used as either diesel fuel or fuel oil, and Chevron calls No. 2 fuel oil similar, but not identical, to No. 2-D diesel. Heating oil is made to the fuel oil standard, ASTM D396.

Does kerosene gel?

Only when it's far colder. The Filter Manufacturers Council puts the cloud and pour points of kerosene and No. 1 diesel near -40°F (-40°C). That's why blending in kerosene is the way to lower the cloud point of No. 2.

Will anti-gel fix heating oil that has already gelled?

Don't count on it. Chevron says cold-flow additives have to go in while the fuel is still above its cloud point, and Cenex says crystals that have already formed stay even after you blend. Warm the oil, replace the plugged filter, then treat or blend it before the next cold night.

Should I keep pressing the reset button?

No. Beckett's NX burner manual says the appliance must be free of oil and oil vapor before you start or reset the burner, and its control goes into a lockout that only a qualified service technician should reset after three lockouts in a row. Find out why it stopped first.

Does Bioheat gel sooner?

A little, at higher blends. Clean Fuels Alliance America says B5 typically clouds at about the same temperature as straight No. 2 diesel, and B20 can cloud about 2 to 7°F higher.

Sources

  1. Glossary: No. 1 and No. 2 fuel oil, No. 2 distillate, U.S. Energy Information Administration
  2. Diesel Fuels Technical Review (2007), Chevron: related products and the ASTM D396 fuel oil table
  3. Technical Service Bulletin 91-1, Solving Winter Diesel Fuel / Fuel Filter Problems, Filter Manufacturers Council
  4. Cold weather diesel problems, Cenex
  5. How Combustion Is Affected by Cold Oil and Air, Beckett technical bulletin (2002)
  6. Beckett Model NX Burner Manual for Weil-McLain Ultra Oil boilers
  7. Homeowners Guide to Heating Oil Tank Systems, Nova Scotia Environment and Labour (2005), via Library and Archives Canada
  8. Biodiesel cold flow management fact sheet (2021), Clean Fuels Alliance America

Updated · By Mechy (Winding AI, Inc.) · How we write these pages

Got a job like this?

Snap the machine and say the job. Mechy makes the steps with tools, parts, safety and a moving drawing for each.

First guide free. No sign-up, no card.

First guide free. No sign-up, no card.

Snap a photo, ask Mechy