Cold-weather fuel check
Will my diesel gel tonight?
No. 2 diesel starts to wax near 14°F (-10°C) and can stop flowing 6 to 20°F lower. Check your night and your fuel here.
Tonight's low against six fuels
What the checker says for a night at each temperature, with no supplier figure entered. Anti-gel here means it went in while the fuel was warm.
We built this from the same sourced numbers as our diesel gelling temperature chart, which has the long explanation. What we think matters most is that the trouble starts at the cloud point, where wax first shows, not at the gel point. That's where filters plug, 6 to 20°F above the temperature where the fuel stops pouring.
| Overnight low | No. 2 | No. 2 + anti-gel | B20 | 30% No. 1 | 50/50 | No. 1 |
|---|---|---|---|---|---|---|
| First wax (cloud point) | 14°F (-10°C) | 14°F (-10°C) | 16 to 21°F (-9 to -6°C) | 5°F (-15°C) | -1°F (-18°C) | -40°F (-40°C) |
| 30°F (-1°C) | Low risk | Low risk | Treat today | Low risk | Low risk | Low risk |
| 20°F (-7°C) | Treat today | Fine | Wax | Treat today | Low risk | Low risk |
| 10°F (-12°C) | Wax | Cloudy, flows | Gel | Treat today | Treat today | Low risk |
| 0°F (-18°C) | Gel | Cloudy, flows | Gel | Wax | Treat today | Low risk |
| -10°F (-23°C) | Gel | Past anti-gel | Gel | Gel | Gel | Low risk |
| -20°F (-29°C) | Gel | Past anti-gel | Gel | Gel | Gel | Low risk |
| -30°F (-34°C) | Gel | Past anti-gel | Gel | Gel | Gel | Treat today |
Wax means first wax forms and the filter is at risk, gel means untreated fuel can stop flowing, and past anti-gel means more than 15°F (8°C) below first wax, beyond what the checker counts an additive for.
Anti-gel buys less room than the big numbers on a bottle suggest. The wax still forms at the same temperature, and a flow improver only helps it through the filter. B20 runs into trouble first, on nights other fuels shrug off. A 50/50 blend holds off wax to about -1°F (-18°C), because each 10% of No. 1 takes about 3°F off. Bobcat's T870 manual runs 50/50 down to -5°F (-21°C), a little past that, so on a night that cold we'd treat the blend as well. Below -5°F, Bobcat goes to straight No. 1.
How the checker reads a 10°F night
This is the night the checker opens with, a 10°F (-12°C) low on No. 2 diesel with no anti-gel.
- Find the cloud point. Cenex puts typical No. 2 at about 14°F (-10°C). Tonight's 10°F is 4°F below it, so wax will form.
- Find where it stops flowing. Chevron says untreated diesel gels 6 to 10°F below that, and the Filter Manufacturers Council says 10 to 20°F. That's -6°F (-21°C) to 8°F (-13°C). Tonight stays just above it, so the fuel should still pour, but Chevron says some fuel systems plug right where wax first shows. The checker calls it wax likely, filter at risk.
- Work out the blend. Getting the cloud point from 14°F to 10°F means taking off 4°F. At 3°F per 10% of No. 1, that's 20% No. 1, which brings first wax to about 8°F (-13°C). It has to go in while the fuel is warm and clear.
- Or count the anti-gel. Had a flow improver gone in while the fuel was warm, the checker would allow 15°F (8°C) more, down to -1°F (-18°C), and read cloudy, should still flow.
- Check the manuals. At 10°F, Bobcat's T870 manual suggests 50/50 No. 1 and No. 2, and Kubota's SVL75 and SVL90 call for No. 1. Your own machine's manual wins.
Where each number comes from
Every threshold in the checker, and who published it. Where a source gives a range, the checker takes the cautious end.
| What the checker uses | Number | Source |
|---|---|---|
| No. 2 first wax, typical | About 14°F (-10°C) | Cenex |
| No. 2 first wax, range | -18 to 20°F (-28 to -7°C), now and then up to 40°F (4°C) | Filter Manufacturers Council |
| No. 1 or kerosene | Near -40°F (-40°C) | Filter Manufacturers Council |
| Blending No. 1 into No. 2 | About 3°F lower per 10% of No. 1 | Chevron, Cenex |
| B20 | 2 to 7°F above straight No. 2. The checker uses 7°F | Clean Fuels Alliance America |
| When to treat or blend | 15°F above first wax, or nights near 30°F | Cenex |
| Where untreated fuel stops flowing | 6 to 10°F below first wax (Chevron), 10 to 20°F below (FMC) | Chevron, Filter Manufacturers Council |
| Anti-gel mixed in warm | 15 to 25°F typical benefit on the flow test. The checker uses 15°F | Chevron |
| Fuel to run by temperature | No. 2 above 15°F, 50/50 to -5°F, No. 1 below (Bobcat T870). No. 1 below 23°F (Kubota SVL75, SVL90) | Bobcat, Kubota manuals |
None of this is the limit of the fuel in your tank. The real figure for what you bought can sit well away from the typical figure, which is why the checker takes your supplier's number when you have it.
Machine won't start, or the fuel already gelled?
Warm the fuel until the wax melts, a heated building being the simple way, and keep open flame away from it. Then replace the plugged fuel filter and bleed the air before you crank. A late dose of anti-gel won't clear wax that has already formed. The full steps are on our gelling page.
Not sure it's the fuel? Snap the machine and say what it's doing, and Mechy lays out the checks and the steps for yours, with the safety first.
Questions
How does the checker decide if my diesel will gel?
It compares tonight's low with the temperature where your fuel starts to wax, its cloud point. More than 15°F above it is low risk. Within 15°F is when Cenex says to switch to a winter blend. At or below it, wax forms and the filter is at risk, and 6°F or more below it untreated fuel can stop flowing, by Chevron's figures.
Why does it use the overnight low?
Because the fuel in a parked machine gets that cold. In the field test ASTM D975 describes, 30% of the parked vehicles had tank fuel within 2°C (about 4°F) of the overnight low. Daytime highs don't matter much if the machine sits outside all night.
Does anti-gel change the answer?
Only if it went in while the fuel was warm. The checker then counts on 15°F (8°C) more before the filter is at risk, the low end of the 15 to 25°F typical benefit Chevron gives for flow improvers. The fuel still hazes at the same temperature, since the Filter Manufacturers Council says these additives change the shape of the wax crystals rather than stop them forming.
What if I don't know what's in the tank?
Pick the winter blend option and the checker treats the fuel as straight No. 2, the cautious choice. Better still, ask your supplier for its first-wax temperature and type it in. ASTM's diesel standard leaves that number to the supplier and the buyer, and suppliers print it: Growmark's No. 2 sheet gives 5°F.
Is B20 worse in the cold?
A little. Clean Fuels Alliance America says B20 can cloud about 2 to 7°F higher than straight No. 2, and B5 about the same as No. 2. The checker uses 21°F for B20, the warmer end. Some machines also limit biodiesel, and Bobcat's T870 manual allows no more than 5%.
Can I use this for a heating oil tank?
Roughly. No. 2 heating oil is close to No. 2 diesel but made to its own standard, so ask your oil company for its figure and type that in. Our page on whether heating oil freezes covers the tank, the outdoor line and the burner.
Sources
- Cold weather diesel problems, Cenex (No. 2 cloud point about 14°F; switch 15°F above it or when nights near 30°F; 3°F per 10% No. 1). Cenex rewrote the page on Nov 11, 2026, so this is the copy the Internet Archive saved on March 11, 2026
- Technical Service Bulletin 91-1, Solving Winter Diesel Fuel / Fuel Filter Problems, Filter Manufacturers Council (No. 2 cloud point -18 to +20°F, occasionally +40°F; pour 10 to 20°F lower; No. 1 near -40°F)
- Diesel Fuels Technical Review (2007), Chevron (pour point 6 to 10°F below the cloud point; additive benefits, Table 7.1; 3°F per 10% No. 1-D; additives go in before wax forms)
- ASTM D975-24, Standard Specification for Diesel Fuel, Appendix X5 (tank fuel within 2°C of the overnight low in 30% of vehicles)
- Bobcat T870 Operation & Maintenance Manual 7253831, fuel by temperature (via Klindex)
- Kubota SVL75 / SVL90 Operator's Manual V0512-5812-4, No. 1-D below 23°F and a full tank overnight (via KubotaBooks)
- Biodiesel cold flow management fact sheet (2021), Clean Fuels Alliance America (B5 clouds like No. 2; B20 about 2 to 7°F higher)
- No. 2 Diesel Fuel product sheet (revised March 2021), Growmark (one supplier's cloud point: 5°F)
Updated · By Mechy (Winding AI, Inc.) · How we write these pages