In short
To remove a rusted bolt, soak it in penetrating oil (15 to 30 minutes, or overnight for heavy rust), tap it to crack the rust, turn it with a six-point socket or a box-end wrench, and rock it back and forth rather than heaving on it. If it still won't move, soak it again before you add force, then try heat, with the penetrant washed off first. If the head rounds or the bolt snaps, a nut splitter, an extractor or a saw finishes the job.
The bolt has been there since the machine's second owner, and it would like to stay. Rust is iron that gave up its career and took up holding on, and it's very good at it. The trick is to be more patient than the bolt, which is harder than it sounds, because the bolt has had a lot of practice.
Step 1: Clean it and soak it
Kroil's first step is to clean the loose rust off, so the oil goes into the threads instead of onto the crust. Then spray the threads.
How long to wait depends on who you ask:
| Source | Soak time |
|---|---|
| Kano Laboratories (Kroil) | 15 to 30 minutes; several hours or overnight for heavy rust |
| Family Handyman | At least 15 minutes |
| WD-40 Company | Several minutes, then reapply and repeat |
Kroil's instructions add a second coat before you try, and turning it while the penetrant is still wet. Penetrating oil is patience in a can. It works better if you bring some patience of your own.
Step 2: Shock the rust loose
Family Handyman's move is a few sharp hammer blows on the bolt head, then more penetrant, then repeat. The shock cracks the rust so the oil can wick in.
Kroil's maker says the opposite: avoid sudden impact until the fastener starts to move. When two sources disagree, start with the gentler one.
Step 3: Use the right wrench
Use a six-point socket or a box-end wrench. TEKTON says a six-point tool is less likely to slip, especially on a damaged or rusted fastener, and Jalopnik says to skip the open-end wrench. A twelve-point socket on a rusty bolt is how a hex becomes a circle.
If you go for an impact wrench, use impact-rated sockets. Family Handyman warns that ordinary sockets may crack or shatter under an impact gun.
Not sure what size the bolt is under all that rust? The bolt size chart lists the wrench size for each bolt, inch and metric.
Step 4: Rock it, don't yank it
Turn it a little one way, then a little the other, while the penetrant is still wet. Kroil calls for alternating tightening and loosening, and Jalopnik says one long pull is how you snap the head off. Each small move lets a bit more oil into the threads.
Stop adding force when it won't budge. Kroil's instructions say to repeat the soak rather than lean harder, because too much torque breaks the fastener. No source gives a number for when to quit, so treat "it didn't move" as the signal to soak again, not to find a longer bar.
Step 5: Add heat (carefully)
Heat is the next step up in every source here, and the one that needs the most care.
Warning: penetrating oil burns. Kano Laboratories says penetrants like Kroil are flammable and must never be used around an open flame. Wipe and wash the penetrant off before you light a torch, and never spray it onto a hot part.
Warning: a torch can start a fire you can't see. Bernzomatic's manual says never to use the torch on or near anything combustible and to watch for hidden fuel lines and tanks. Take off rubber and plastic parts nearby, wear safety glasses and gloves, and keep a fire extinguisher and a bucket of water within reach.
Family Handyman heats for about 15 seconds and says never to go to cherry red, because that ruins the bolt's temper. Jalopnik heats for longer, so the sources differ: start short. Then quench it with water, let it cool, and apply penetrant again before you turn it.
Step 6: More leverage, last
A longer breaker bar gives more leverage, which is exactly why it snaps bolts. Family Handyman says to go slow and warns that a cheater pipe can weaken or snap the tool itself. The bar got longer; the bolt didn't get any weaker.
Jalopnik calls the impact wrench a last resort: lowest setting, short bursts.
Which penetrating oil works best?
The test everyone quotes is from Machinist's Workshop (April/May 2007). It measured the load it took to free rusted pins after soaking, three samples each:
| Penetrant | Average load to break free |
|---|---|
| ATF and acetone mix | 53 lb |
| Kroil | 106 lb |
| Liquid Wrench | 127 lb |
| PB Blaster | 214 lb |
| WD-40 | 238 lb |
| Nothing | 516 lb |
Two catches. It tested rusted dowel pins in steel rings, not bolts, as the article says plainly. And three samples is a small test. What it does show is that any penetrant beats none, and that the classic blue-and-yellow can isn't the strongest one in the drawer. Family Handyman agrees that original WD-40 isn't formulated as a rust penetrant; the WD-40 Company sells a separate penetrant for that.
When the head rounds off or the bolt snaps
It happens to everyone. Here's what each source reaches for:
- Rounded nut: a nut splitter cracks the nut without hurting the bolt's threads (Family Handyman). Or cut it off with a reciprocating saw, hacksaw or rotary tool.
- Rounded bolt head: a pipe wrench can bite on what's left (Family Handyman), or weld a nut onto the head and turn that (This Old House).
- Snapped bolt: drill a centered hole and turn a bolt extractor counterclockwise. Its left-hand taper jams in and backs the bolt out. This Old House says to pick an extractor a little smaller than the bolt and drill slowly, small bit to large, with cutting oil. A left-hand drill bit sometimes backs the broken bolt out on its own.
Don't snap the extractor. Jalopnik says a broken extractor is very hard to drill out. An extractor stuck in a bolt stuck in a hole is a very bad afternoon.
Wood screw instead of a bolt? That's its own job: see how to remove a stripped screw.
How to keep the next one from seizing
Put anti-seize on the threads when it goes back together. This Old House says to use it sparingly, so it doesn't throw off the torque.
It does change the torque, and the sources don't agree on what to do about it:
- Fastenal's tables give lower torque for lubricated threads. For an M10 class 8.8 bolt, 37.8 N·m lubricated against 50.5 N·m dry.
- Loctite says anti-seize gives more clamp load for the same torque than a clean, dry bolt.
- Permatex says to reassemble with normal torque values.
So follow your manual. If it gives a dry torque and you're using anti-seize, ask the maker which applies. Using an extension on your torque wrench? The torque wrench extension calculator gives the setting. If you have to replace the bolt, what size bolt do I need covers how to measure it.
Got a bolt you can't even identify under the rust? Snap a photo and Mechy tells you the size and thread, and the steps for your job.
Questions
How long should penetrating oil soak on a rusted bolt?
Kroil's maker says 15 to 30 minutes, and several hours or overnight for heavy rust, with a second coat before you try again. Family Handyman says at least 15 minutes. WD-40 says to soak for several minutes, then reapply and repeat if it's still stuck.
Is WD-40 a penetrating oil?
The classic WD-40 isn't sold as one: Family Handyman says it is not formulated as a rust penetrant. The WD-40 Company sells a separate Specialist Penetrant for stuck parts, and in a 2007 Machinist's Workshop test on rusted pins, plain WD-40 needed more force to break free than any dedicated penetrant tested, though far less than no penetrant at all.
Should I heat a rusted bolt?
Heat helps, but never with penetrating oil on it: Kano Laboratories says penetrants like Kroil are flammable and should never be used around an open flame. Wash the penetrant off, keep the flame away from fuel lines and anything that burns, heat briefly (Family Handyman says about 15 seconds, never cherry red), let it cool, then apply penetrant again.
How do I get a bolt out if the head is rounded or snapped off?
For a rounded head, a nut splitter cracks a seized nut without hurting the bolt's threads, and a bolt extractor or a welded-on nut can grip what's left. For a snapped bolt, drill a centered hole, small bit to large, and turn an extractor counterclockwise. Don't snap the extractor: it's far harder to drill out than the bolt.
Do you change the torque when you use anti-seize?
Check your manual first, because the sources disagree. Fastenal's torque tables give lower torque for lubricated threads (for an M10 class 8.8 bolt, 37.8 N·m lubricated against 50.5 N·m dry), and Loctite says anti-seize gives more clamp load for the same torque. Permatex says to reassemble with normal torque values.
Sources
- Kroil Original Penetrant, Kano Laboratories: how to use it
- To torch or not to torch? That's the question with stuck fasteners, Fleet Maintenance (Kano Laboratories)
- How Penetrating Oil Works: The Science Behind the Spray, WD-40 Company
- Tips for Loosening Nuts, Bolts and Screws, Family Handyman
- Free Up Stuck Bolts in 5 Easy Steps, Family Handyman
- How To Remove A Stuck Bolt (Without Breaking It), Jalopnik (2025)
- How To Remove a Stubborn Stripped Bolt, This Old House
- Which is Better in Sockets and Wrenches? 6-Point vs. 12-Point, TEKTON
- Bernzomatic TS99 / MT555 torch manual: safety warnings
- Testing Different Types of Penetrating Oils, Machinist's Workshop, April/May 2007, p. 35 (scan)
- Technical Data Sheet, LOCTITE LB N-1000 anti-seize, Henkel
- Torque-Tension Relationship, ISO 898-1 Property Class 4.6, 8.8, 10.9 and 12.9, Fastenal
- Technical Data Sheet, Permatex Copper Anti-Seize Lubricant (retailer copy)
Posted · By Mechy (Winding AI, Inc.) · How we write these pages