Electric feed pump on a gold concentrator
Concentrator feed pump wiring
Loose connections interrupt the concentrator's feed pump, and the equipment ground burns.
- 3 h
- Hard
- 8 steps
- 12 tools

Made by AI. A mechanic hasn't checked it line by line yet. Use it to plan the job, and follow the maker's manual for specs and procedures.
Safety first
Shop or dealer jobDo these before step 1.
- DANGERSpark plug: pull the wire before you touch the blade.
- WARNINGBattery: isolator off, negative terminal off first.
- DANGERElectrical: lock out every source; prove dead before touching.
- WARNINGMovement: chock the skid and crib anything raised or unstable.
- WARNINGSlurry: isolate, depressurize and drain before opening the pump.
Stop and call a pro or the dealer if
- Call a qualified electrician if the ground fault source or grounding arrangement is unresolved.
- Stop for damaged windings, carbon tracking or failed insulation; consult the motor shop or dealer.
Mechy's guides help, but they don't replace the maker's manual, your training or your site's rules. If something doesn't match what you see, stop and check.
Tools
Tick what you have. In the app, Mechy ticks the ones it can see in your photos.
Parts and supplies
- 1×Replacement conductorsMatch circuit ampacity, voltage, temperature and wet-location requirementsCheck before you buy
- 1×Listed wire terminalsMatch conductor material, strand class, size and terminal hardwareCheck before you buy
- 1×Equipment grounding conductorSize to circuit protection and applicable electrical codeCheck before you buy
- 1×Junction box gasketMatch enclosure and environmental ratingCheck before you buy
- 1×Pump cover sealMatch pump and slurry serviceCheck before you buy
Steps
Step 1 of 8
Isolate and prove dead
Lock out all feeds; prove dead, chock the skid, then isolate and drain the slurry.
Generator off, key out, battery isolated; tag controls and block movement.
Lockout kit, Voltage tester, Chocks and rated cribbing, Drain pan
Step 2 of 8
Open the inspection points
Remove the box lid and suction cover without pulling wires or damaging seal faces.
Lift the box lid upward; the suction cover comes forward.
Insulated hand tools, Socket set
Step 3 of 8
Find the failure
Check impeller freedom; trace heat damage, loose crimps and the ground fault source.
A burned ground needs fault investigation, not just a new wire.
Insulated hand tools
Step 4 of 8
Renew damaged terminations
Replace burned wiring to sound copper; strip and crimp matched listed terminals.
Record lead identities; replace damaged blocks, glands or cable as needed.
Wire stripper, Matched crimp tool
Step 5 of 8
Torque and secure
Reconnect by the motor diagram; torque terminals and secure the cable gland.
Terminal and gland torque: Use motor, terminal and gland manufacturer labels or manuals Check it against your manual.
Torque screwdriver, Insulated hand tools
Step 6 of 8
Verify the repair
Test ground continuity and motor insulation; verify supply and protection ratings.
Disconnect sensitive electronics before insulation testing; discharge afterward.
Electrical acceptance: Use OEM test procedure, nameplate and applicable electrical Check it against your manual.
Low-resistance tester, Insulation tester, Voltage tester
Step 7 of 8
Reseal and close
Renew seals, refit covers, torque fasteners and restore the primed slurry circuit.
Cover fasteners: Check pump and motor OEM manuals Check it against your manual.
Torque screwdriver, Socket set
Step 8 of 8
Controlled loaded test
Clear personnel, release lockout, start the generator and check pump flow and load.
Use enclosed test access; stop for trips, leaks, heat or abnormal current.
Operating limits: Verify voltage, current and rotation against nameplate and Check it against your manual.
Clamp meter, Voltage tester