Usually you don't: a Kubota tractor regenerates its DPF by itself while you work. If the regen light flashes, keep working, and raise rpm if the rpm-up light flashes too. If the light with a P flashes, park, set the brake, shift to neutral, PTO off, idle, and press the parked regeneration switch. It takes about 15 to 20 minutes.

Stuck on this? Snap a photo and ask Mechy. It makes the steps for what you have, with tools, parts and a moving drawing for each. First guide free. No sign-up, no card.

Snap a photo, ask Mechy

A regen burns off the soot (particulate matter, PM) that the diesel particulate filter traps. The steps below come from five Kubota tractor operator's manuals: L3301/L3901, MX4800 to MX5800, M5-091/M5-111, MX5400/MX6000 and LX3310. They agree on the method, but switch names and engine speeds vary by model, so check yours.

What the regen lights mean

Light or switchWhat it looks likeWhat it meansWhat to do
Regeneration indicator, flashingDPF symbol: a dotted filter with exhaust curlsSoot has built upKeep working. The regen starts by itself
Regeneration indicator, on steadySameA regen is runningKeep working until it goes out
Engine rpm increase indicator, flashingUp arrow in an engine outline, r/minEngine too slow to regenRaise rpm until it goes out
Parked regeneration indicator, flashingDPF symbol with a PA parked regen is duePark and run a parked regen
DPF inhibit switch lamp, onDPF symbol crossed outAuto regen is switched offPress it to go back to auto
Engine warning indicator, flashingExclamation mark in an engine outlineLevel 3: power cut to 50%Stop work and run a parked regen
Engine warning indicator, on steadySameLevel 4Park, engine off, call the dealer

Those are only the regen lights. For the oil, charge, overheat and master lamps, and which of them your model has, see Kubota warning lights.

Auto regen: what to do when the light flashes

  1. Start the engine and check that the DPF inhibit lamp is off. Auto regen comes on at every start.
  2. When the regeneration indicator flashes, keep working. The regen begins by itself, so stay somewhere safe: the exhaust and the DPF get hot.
  3. If the rpm-up indicator flashes, keep working at higher rpm until it goes out. Under heavy load it can keep flashing even after the regen has started.
  4. The regeneration indicator stays on during the regen and goes out when it's done.

A regen only runs while the coolant and the DPF are hot enough and the engine turns fast enough: 1,200 rpm or more in the L3301/L3901, MX and M5 manuals, 1,600 rpm on the LX3310. If any of these drops, the regen stops. Kubota says to avoid long idling: at low speed and load the exhaust stays cool, soot builds faster and you'll need regens more often.

How to do a parked regen

Do this when the parked regeneration indicator, the light with a P, flashes. If the auto regen keeps getting cut short, this is the way to finish it.

  1. Park in a safe area away from buildings, people, animals and anything that burns.
  2. Apply the parking brake.
  3. Put the shuttle lever (gear models) or the speed pedal (HST models) in neutral.
  4. Turn the PTO off.
  5. Bring the engine back to idle.
  6. Lower the implement to the ground and point the front wheels straight ahead.
  7. Check the DPF inhibit lamp is off. If it's on, press the switch.
  8. Wait for the parked regeneration switch lamp to flash. It only flashes once the brake, neutral, PTO, idle and inhibit settings are right.
  9. Press the parked regeneration switch. Its lamp stays on, the rpm rises by itself and the regen starts.
  10. Stay with the tractor. When the switch lamp and the regeneration indicator both go out, it's done.

During the regen, don't touch the levers, the PTO or the throttle except for an emergency stop, or the regen ends. If it does get interrupted, the engine is held at idle for about 30 seconds and the throttle won't respond until then. White exhaust can show during a regen, so never run one in a closed garage. The engine may also sound different, because its airflow is limited to keep the exhaust hot. That's normal, per Kubota. When it's finished, leave the engine running for about 5 minutes so the exhaust cools.

Kubota DPF warning levels

If a regen keeps failing or gets ignored, the soot level climbs through Kubota's PM warning levels. This is the auto-mode table from the L3301/L3901 manual. The MX4800, M5 and MX5400 manuals show the same levels.

LevelBuzzerEngine powerLightsWhat to do
1SilentFullRegen light flashes, rpm-up light may flashKeep working at higher rpm
2-1Every 5 secondsFullRegen light flashesGet the regen going, as in level 1
2-2Every 3 secondsFullRpm-up and P lights flashRaise rpm, or run a parked regen
3Every second50%Engine warning and P lights flashStop work and run a parked regen now. Auto regen no longer works
4Every second50%Engine warning light on steadyPark, engine off, call your Kubota dealer

At level 4, Kubota says not to keep running the tractor, or the DPF and engine will be damaged. On the M5-091 and M5-111, the meter can also show soot build-up as a percentage, and a regen is needed at 100%.

The regen inhibit switch

Pressing the DPF inhibit switch after starting the engine turns its lamp on and stops automatic regens. Kubota suggests it for work in poorly ventilated spaces. The soot doesn't go away, though:

  • Inhibit mode resets. Stop the engine once and the tractor is back in auto regen.
  • The warnings still come. In inhibit mode, levels 2-1 and 2-2 tell you to move somewhere safe and run a parked regen.
  • You can switch back. From level 1 to 2-2, turning inhibit off lets the auto regen run instead.

Kubota regen won't start?

Run through what the manuals list before calling the dealer:

  • Inhibit lamp on? Press the switch to turn it off. Restarting the engine does the same.
  • Parked switch lamp not flashing? One of the conditions isn't met: parking brake, neutral, PTO off, engine at idle, inhibit off.
  • Engine cold? A regen needs hot coolant and a hot DPF. Kubota recommends regenerating while the engine is warm.
  • Regen just got interrupted? Wait out the 30 seconds at idle, then start again.
  • Engine warning light on steady? That's level 4: engine off and call the dealer.
  • Regens coming too often? Long idling is the usual reason. Kubota also calls for ultra-low sulfur diesel (S15) and CJ-4 engine oil, and says other oils can clog the DPF early.

Ash, the burnt residue a regen leaves behind, still builds up. The L3301/L3901 maintenance chart lists cleaning the DPF every 3,000 hours, by a Kubota dealer with a special cleaning device. Don't take the DPF apart yourself. The daily checks include looking over the DPF and the area around it for anything that could catch fire.

Kubota skid steers and track loaders

Kubota's SSV skid steers and SVL track loaders also have a regen inhibit switch: Kubota code E9006 means a regen is due but that switch is on. The SSV65 manual says auto regen is set at every start and runs by itself unless that switch is engaged. It lists the conditions as coolant above 65°C (149°F), DPF above 250°C (482°F) and the engine above 1,200 rpm. If the rpm is too low, the regeneration indicator blinks: rev the engine until the rev-up lamp goes out and the regen starts. It usually takes about 15 to 20 minutes, and you shouldn't leave the machine during it.

These loaders show DPF codes on the display. Two transcriptions of Kubota's operator's manual table agree on these:

CodeMeaningWhat to do
E:9000, E:9001Regen needed, engine rpm too lowRaise the rpm so the regen can start
E:9002"DPF is regenerated", a status messageNothing: the table lists no action
E:9003Regen needed but can't startCall your dealer
E:9004DPF needs replacingCall your dealer
E:9006, E:9007Regen needed, inhibit switch is onMove somewhere safe and release the switch
E:9010Engine stopped itself for the DPFRestart, move somewhere safe, release the inhibit switch
E:9212, E:9213, E:9214Regen timed out, coolant too cold, or regens too oftenCall your dealer

E:9001, E:9007 and E:9010 come with a warning: leave the machine with the hydraulics locked and the engine can stop by itself. The rest of the list is on our Kubota fault codes page. If the regen on your loader still won't run or finish, our page on a skid steer regen that won't finish covers the usual causes, Bobcat and Takeuchi too, and when the DPF needs cleaning.

Model differences in the manuals

ManualRegen needs at leastUsual regen timeNotes
L3301, L3901 (2016)1,200 rpm15–20 minParked regen and inhibit switches on the dash
MX4800, MX5200, MX5800 (2013)1,200 rpm15–20 minSame levels and steps
M5-091, M5-111 (2015)1,200 rpm15–20 minMeter shows soot build-up in %. Regen fuel can raise the engine oil level
MX5400, MX6000 (2019)1,200 rpm15–20 minPTO is a switch, not a lever
LX3310 (2020)1,600 rpm15–20 minDPF switches are marked LX3310 only, not LX2610
SSV65 skid steer1,200 rpmAbout 15–20 minCoolant above 65°C, DPF above 250°C

Not sure which light is on, or what a code on the loader's display means? Snap the dash and Mechy tells you what it means and what to check first.

Questions

How do you regen a Kubota tractor?

Usually you keep working. With the DPF inhibit lamp off, the tractor regenerates by itself once enough soot has built up and the engine is hot and fast enough. If the rpm-up light flashes, raise engine rpm until it goes out. If the light with a P flashes, park, set the brake, shift to neutral, turn the PTO off, idle and press the parked regeneration switch.

What is the Kubota regen light with a P?

It's the parked regeneration indicator. When it flashes, a parked regen is due: PM warning level 2-2 or higher in Kubota's tables. Park somewhere safe and run the parked regeneration.

Why is my Kubota regen light flashing?

A flashing regeneration indicator means a set amount of soot has built up in the DPF. Keep working so the exhaust gets hot. Once the regen starts, the light stays on, then goes out when it's done. If the buzzer sounds too, the regen was cut short or couldn't start.

How long does a Kubota regen take?

Kubota's tractor manuals say it usually takes 15 to 20 minutes, depending on air temperature, exhaust temperature and engine speed. The SSV65 skid steer manual gives the same range. Afterwards, let the engine run about 5 minutes so the exhaust can cool.

What does the regen inhibit switch do on a Kubota?

It stops automatic regens, for jobs where hot exhaust is a problem, such as poorly ventilated spaces. Soot keeps building, so you'll have to run a parked regen later. Every time the engine is restarted, the tractor goes back to auto regen.

What happens if you interrupt a Kubota regen?

The soot stays, and the warning level climbs if you keep working. Kubota also warns that starting and stopping regens for no reason mixes a little fuel into the engine oil. If you stop a parked regen, the engine is held at idle for about 30 seconds.

Sources

  1. Kubota L3301, L3901 Operator's Manual TC620-1973-8 (2016), exhaust aftertreatment devices and periodic service (via KubotaBooks)
  2. Kubota MX5400, MX6000 Operator's Manual TC860-1971-5 (2019), exhaust aftertreatment devices (via KubotaBooks)
  3. Kubota MX4800, MX5200, MX5800 Operator's Manual TC650-1971-2 (2013), DPF regeneration (via KubotaBooks)
  4. Kubota M5-091, M5-111 Operator's Manual 3B291-9971-2 (2015), DPF regeneration and engine oil (via KubotaBooks)
  5. Kubota LX2610, LX3310 Operator's Manual 6C830-6311-3 (2020), exhaust aftertreatment devices (via KubotaBooks)
  6. Kubota SSV65 Operator's Manual, DPF regeneration indicator (page 45, via ManualsLib)
  7. Kubota SSV65 Operator's Manual, regeneration of the DPF (page 46, via ManualsLib)
  8. CodeReady, Kubota skid steer loader error codes (SVL/SSV operator's manual table)
  9. PDF Manual 4 Trucks, Kubota SVL90 error (fault) codes list (operator's manual table)