Mechy Try it free

Learn

Skid Steer or Track Loader Regen Won't Finish

In short

Don't force it yet. A regen that won't start or finish is usually blocked by the inhibit switch, low rpm, a cold engine, a DEF fault or a bad sensor. Clear the cause and the machine regens by itself. Run a parked regen only if your loader has one. Ash needs a cleaning, not a new filter.

Stuck on this? Snap a photo and ask Mechy. It makes the steps for what you have, with tools, parts and a moving drawing for each. First guide free. No sign-up, no card.

Snap a photo, ask Mechy

Everything here comes from the makers' own manuals and fault lists, the same ones behind our Kubota code pages like E9006 and E9000. That matters because AI answers get these codes wrong. When we asked about E9006, Google's AI Mode called it an injector fault and Gemini called it a level 4 warning. Kubota's SVL97-2 manual says it means a regen is due but the inhibit switch is on. Check the code on your panel against the maker's table before you trust anyone's guess, ours included.

How a loader cleans its own filter

The diesel particulate filter (DPF) traps soot, and a regen burns it off with hot exhaust, usually while you work. On Kubota's SVL loaders auto regen is the default every time the engine starts. It begins once the coolant is above 65°C (149°F), the DPF is above 250°C (482°F) and the engine is turning over 1,200 rpm, and it usually takes 15 to 20 minutes. Kubota says not to leave the machine while it runs.

If your work never gets the filter hot enough, some machines let you run a parked (manual) regen with the loader standing still. Once the soot builds up past that, only the dealer's service regen will clear it.

StageKubota SVL65-2, SVL97-2Bobcat M-Series loadersTakeuchi TL6R
Automatic regenOn at every start. Needs coolant above 65°C, DPF above 250°C and over 1,200 rpmM8541 or M8542, "DPF automatic regeneration active"Runs by itself when the engine's conditions are met
InhibitThe switch stops auto regen. E:9006 or E:9007 when a regen is dueM8551 or M8552, "regeneration needed, inhibit active"The inhibit side of the switch cancels a regen. Use it only for a fire risk
Parked regenNo steps in the operator's manualsM8553 asks for a remote parked regen, done with Bobcat's kitHold the manual side of the switch at low idle
DealerE:9003, a regen is needed but can't startM8554 "service regeneration required, contact Bobcat dealer"ECM warning flashing with an engine error code
Ash cleaningEvery 3,000 hours, by the dealerP242F "ash cleaning needed" on Bobcat engine V2Every 6,000 hours, or when the ash lamp flashes

Why the regen won't start or finish

Start with the inhibit switch, because it costs nothing to check. On a Kubota SVL one press turns auto regen off and the next turns it back on, and E:9006 or E:9007 on the panel means it's off. Bobcat shows M8551 or M8552. On a Takeuchi the inhibit side cancels a regen that's already running, and so does turning the key off.

Heat comes next. Kubota tells SVL owners not to idle more than they need to, since low rpm keeps the exhaust too cool to burn soot. Short jobs with a lot of idling fill a filter fast. E:9000 and E:9001 mean the rpm is too low, E:9213 means the coolant is too cold, and E:9214 means regens are coming too often. Takeuchi's manual regen won't start until the coolant warms up, and Bobcat's list has P3012 for low water temperature during a parked regen.

Then look for whatever interrupts it. Takeuchi says lowering the safety bar or moving the levers stops a regen. Kubota warns that a machine left with the hydraulics locked can shut its engine off during E:9001, E:9007 and E:9010. Every repeated or interrupted regen also mixes a little more fuel into the engine oil, Kubota says, so check the oil after several tries and change it if the level is above the upper mark.

On machines with SCR, DEF matters too. The SVL97-2 manual says low or poor DEF, or an SCR fault, can keep both auto and parked regens from working properly. A frozen DEF tank blocks the regen until it thaws, and our page on whether DEF freezes covers cold-weather use.

Sensors come last, and they're dealer work. Kubota lists the differential pressure sensor (E:9204), the exhaust temperature sensors (E:9205 to E:9208) and a regen timeout (E:9212), and its answer to each is to contact the dealer. Bobcat's list has the same kinds of faults, plus P246B for a failed regen and P3013 for a parked regen that timed out.

Sometimes there's simply too much soot. Takeuchi says that if you keep working after the regen lamp flashes, power drops until the engine stops. On Bobcat engines P24A3 means the soot is so high that only a service regen will clear it, and P246C means the filter is plugged.

How to start a parked regen on each brand

Kubota SVL

The SVL65-2 and SVL97-2 operator's manuals cover auto regen and the inhibit switch and nothing more. The SVL97-2 mentions a manual (parking) regen in its DEF notes but never gives the steps. Turn inhibit off, warm the engine, work it above 1,200 rpm and allow the full 15 to 20 minutes. If E:9003 appears, or a code is still on after that, it's a job for your Kubota dealer. Kubota tractors work differently, and our guide on how to regen a Kubota tractor covers their parked regen.

Bobcat

Do what the panel asks. M8553 reads "remote parked regeneration required (remote regeneration kit required)". Bobcat sells that kit as part 7218446 for the T750, T770, T870, S750, S770, S850 and A770, and it comes with installation instructions. For running the regen itself, follow the Operation & Maintenance manual for your model. M8554 sends you to the dealer.

Takeuchi

The TL6R manual gives these steps for when the regen lamp flashes and the alarm sounds.

  1. Warm up the engine, because the manual regen won't start until the coolant is warm.
  2. Park where nothing nearby can burn, such as dry grass, trees, paper or oil. Stay out of poorly ventilated buildings and keep the engine hood closed.
  3. Raise the safety bar to the lock position and bring the engine down to low idle.
  4. Press and hold the manual side of the regen switch. When the lamp stops flashing and stays on, the engine speeds up by itself and you can let go.
  5. Stay with the machine. The regen takes about 15 to 20 minutes, depending on the outside temperature, and the lamp goes out when it's done.

Pressing the switch early does nothing, because Takeuchi's regen only starts once the soot passes a set amount.

Clean or replace the DPF?

A regen turns soot into ash, and ash stays in the filter until someone cleans it out. The makers schedule that cleaning. Kubota says every 3,000 hours, done by the dealer with a special machine, and never by taking the filter apart, shaking it or heating it. Takeuchi says every 6,000 hours, or sooner if the ash lamp flashes. Keep running for 200 hours after that lamp and the engine drops to half power. On Bobcat engines, P242F asks for an ash cleaning.

Replacement is for a filter the maker says is finished, like Kubota's E:9004, "you must replace the DPF". Takeuchi adds that a DPF which has been dropped shouldn't go back on, because the catalyst inside can break. A filter that's only full of soot may come back with a service regen. Before you pay for a new one, ask which code calls for it and whether a service regen or a cleaning was tried, and get written quotes for both. Fix whatever blocked the regen as well, or the new filter will fill up the same way. Kubota says the wrong fuel or oil (it wants S15 diesel and CJ-4 oil) and skipped air and fuel filter changes all shorten the time between cleanings.

Why we won't tell you to delete it

Deleting the DPF is illegal. EPA's tampering policy says the Clean Air Act's ban on removing or defeating emission controls covers nonroad engines, construction equipment included, and it names diesel particulate filters among those controls. The rule itself is 40 CFR 1068.101. Kubota's warranty doesn't apply to a machine that wasn't operated and maintained the way its manual says, and Takeuchi warns that modifying the DPF can mean an expensive repair. A delete also leaves whatever stopped the regen unfixed.

Got a code on the display you can't place? Snap the panel and Mechy tells you what it means and what to check first.

Questions

How do I force a regen on a skid steer or track loader?

First find out why the automatic regen stopped, because forcing it won't fix a switch, a cold engine or a sensor. Then use the parked regen your machine has. On a Takeuchi TL6R you warm up, park, lock the safety bar, idle and hold the manual side of the regen switch. Bobcat asks for a remote parked regen on some models, done with its kit. Kubota's SVL manuals give no parked regen steps, so a regen that can't start there is a dealer job.

Does a Kubota SVL have a parked regen?

Not in the SVL65-2 or SVL97-2 operator's manuals. They describe automatic regen and the inhibit switch only. Turn the inhibit switch off, warm the engine and keep it above 1,200 rpm. If the panel shows E:9003, the regen is needed but can't start, and Kubota says to call your dealer.

Why does my regen keep stopping before it finishes?

The manuals point to the inhibit switch, low engine rpm or too much idling, a cold engine, a DEF or SCR fault, or a failed exhaust sensor. On a Takeuchi, lowering the safety bar or moving the levers also stops it. Each interrupted regen mixes a little fuel into the engine oil, so check the oil level after several tries.

How long does a loader regen take?

Kubota's SVL manuals and Takeuchi's TL6R manual both say about 15 to 20 minutes. Kubota adds that the time depends on the outside temperature, the exhaust temperature and how much soot is in the filter. Both say to stay with the machine while it runs.

Can a DPF be cleaned instead of replaced?

Yes, when the problem is ash, which a regen can't burn off. Kubota schedules a dealer cleaning every 3,000 hours and Takeuchi every 6,000 hours or when the ash lamp flashes. Replacement is for a filter the maker's code or the dealer says is done, such as Kubota's E:9004.

Is it legal to delete the DPF on a skid steer?

No. EPA says the Clean Air Act's ban on removing or defeating emission controls covers nonroad engines, construction equipment included, and it names diesel particulate filters. A delete can also cost you the warranty.

Sources

  1. Kubota SVL97-2 Operator's Manual, warranty p. 25, inhibit switch p. 39, DPF regeneration pp. 44-45, SCR and DEF p. 46, DPF cleaning p. 118, error codes pp. 133-136 (Kubota)
  2. Kubota SVL65-2 Operator's Manual V0216-5811-3, inhibit switch p. 39, DPF regeneration pp. 46-47, error codes p. 119 (Kubota)
  3. Bobcat Diagnostic Service Codes, M-Series loaders and Bobcat engines (revised October 2020, Bobcat Company)
  4. DPF Remote Parked Regeneration Kit 7218446, Bobcat parts store (read 2026-11-10)
  5. Takeuchi TL6R Operator's Manual, DPF switch pp. 2-40 to 2-42, cleaning the DPF p. 5-55, ash lamp p. 6-16 (via Hirepool)
  6. EPA Enforcement Policy on Vehicle and Engine Tampering and Aftermarket Defeat Devices (November 2020), U.S. EPA
  7. 40 CFR 1068.101, General compliance provisions for nonroad engines: what the prohibitions are

Updated · By Mechy (Winding AI, Inc.) · How we write these pages

Got a job like this?

Snap the machine and say the job. Mechy makes the steps with tools, parts, safety and a moving drawing for each.

First guide free. No sign-up, no card.

First guide free. No sign-up, no card.

Snap a photo, ask Mechy